Saint-Germainmont (FR)

support our internal process

Specsheet

Model : N90
Intervention : Turbine shut down due to blade conformity problems
Objectives : Installation of 3 second-hand blades

Challenges

  • Blade compatibility – The original blades are no longer manufactured.
  • Timing – Anticipating project management while awaiting permits.

Project Management

  • Blade compatibility survey
  • Dismantling
  • Transport organization
  • Complete refurbishment of blades on site
  • Civil engineering: plate testing, specifications and platform repair
  • Bearing analysis and replacement (cost maximization)
  • Lifting and craning
  • Commissioning and run test
  • Clean up & blade recycling

Our Challenge

innovation & expertise

Chemin d’Ablis (FR)

Saint-Germainmont (FR)

Petit-Caux (FR)